OATEY -- ALL PURPOSE CEMENT, 30848 -- 8040-00N080731
=====================  Product Identification  =====================

Product ID:ALL PURPOSE CEMENT, 30848
MSDS Date:01/01/1996
FSC:8040
NIIN:00N080731
=== Responsible Party ===
Company Name:OATEY
Address:4700 WEST 160TH ST
Box:35906
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Info Phone Num:216-267-7100
Emergency Phone Num:303-623-5716;800-424-9300(CHEMTREC)
CAGE:IO629
=== Contractor Identification ===
Company Name:OATEY
Address:4700 W 160TH ST
Box:35096
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Phone:303-623-5716
CAGE:IO629
Company Name:OATEY CO
Address:4700 WEST 160TH STREET
Box:35906
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Phone:216-267-7100/303-623-5716
CAGE:53472

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 0-5%
OSHA PEL:1000 PPM
ACGIH TLV:750 PPM/1000 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:SILICA, AMORPHOUS FUMED
CAS:112945-52-5
RTECS #:VV7310000
Fraction by Wt: 1-4%
OSHA PEL:6 MG/M3
ACGIH TLV:10 MG/M3

Ingred Name:CHLORINATED POLYVINYL CHLORIDE
CAS:68648-82-8
Fraction by Wt: 3-7%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ETHYLENE, CHLORO-, POLYMER; (PVC RESIN (NON-HAZARDOUS)
CAS:9002-86-2
RTECS #:KV0350000
Fraction by Wt: 8-12%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:CYCLOHEXANONE (CERCLA)
CAS:108-94-1
RTECS #:GW1050000
Fraction by Wt: 11-16%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:FURAN, TETRAHYDRO-; (TETRAHYDROFURAN) (CERCLA)
CAS:109-99-9
RTECS #:LU5950000
Fraction by Wt: 30-45%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/250 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 25-40%
Other REC Limits:N/K 
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: MAY CAUSE IRRIT OF
    MUCOUS MEMBRANES, NOSE & THROAT, HDCH, DIZZ, NAUSEA, NUMBNESS OF
    EXTREMITIES & NARCOSIS IN HIGH CONCS. HAS CAUSED CNS DEPRESSION &
    LIVER DMG IN ANIMALS, & HIGH CONCS H AVE CAUSED RETARDATION OF
    FETAL DEVELOPMENT IN RATS. SKIN: CHRONIC CONT MAY LEAD TO
    IRRITATION & DERM. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: MAY POSSIBLY BE ABSORBED THRU SKIN.
    EYE: VAPORS OR DIRECT CONT MAY CAUSE IRRITATION. INGEST: MAY BE
    ASPIRATED INTO LUNGS OR CAUSE SYSTEMIC EFTS DESCRIBED UNDER
    INHALATION. TARGET ORGANS: EYE , SKIN, KIDNEY, LUNG, LIVER, CENTRAL
    NERVOUS SYSTEM.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. SEEK MED ATTN IF IRRIT
    PERSISTS. EYES: MOVE TO FRESH AIR & IRRIGATE EYES W/WATER FOR @ LST
    15 MINS. IF IRRIT PERSISTS, SEEK MED ATTN. IF EYE IS STRUCK W/WIRE,
    SEE K MED ATTN. INHAL: MOVE TO FRESH AIR. IF BRTHG IS DFCLT, GIVE
    OXYG. IF NOT BRTHG, GIVE ARTF RESP. KEEP VICTIM QUIET & WARM. CALL
    POIS CTL CTR/PHYS IMMED. INGEST: DRINK WATER & CALL POIS CTL
    (SUPDAT)

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:>0F,>-18C
Lower Limits:1.8%
Upper Limits:11.8%
Extinguishing Media:FOR SMALL FIRES: USE DRY CHEMICAL, CO*2, WATER/FOAM
    EXTINGUISHER. FOR LG FIRES:EVAC AREA & CALL FIRE DEPARTMENT IMMED.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA, STOP LEAK IF IT CAN BE DONE
    WITHOUT RISK. TAKE UP WITH SAND, EARTH, OR OTHER NON-COMBUSTIBLE
    ABSORBING MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & FLAMES;
    STORE IN COOL, DRY PLACE.
Other Precautions:CONTAINERS, EVEN EMPTIES WILL RETAIN RESIDUE AND
    VAPORS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED CANNISTER RESPIRATOR IN ABSENCE
    OF ADEQUATE VENTILATION.
Ventilation:GENERAL MECHANICAL: EXHAUST VENT CAPABLE OF MAINTAINING
    EMISSSIONS @ POINT OF USE BELOW PEL. LOC EXHAUST: OPEN (SUPDAT)
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: CTR/PHYS IMMED. AVOID ALCOHOLIC BEVERAGES. NEVER GIVE
    ANYTHING BY MOUTH TO UNCON PERSON. VENT: DOORS & WINDOWS. IF USED
    IN ENCLOSED AREA, USE EXHAUST FANS.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:151F,66C
Vapor Pres:145 @ 20C
Vapor Density:2.5
Spec Gravity:0.90+/-0.02
Evaporation Rate & Reference:5.5-8.0 (BUAC =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:MILKY LIQUID, ETHER-LIKE ODOR.
Percent Volatiles by Volume:84-88

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZING MATLS, ALKALIS, CHLORINATED INORGANICS(POTASSIUM,
    CALCIUM & SODIUM HYPOCHLORITE), COPPER/COPPER ALLOYS.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE/CARBON
    DIOXIDE/HYDROGEN CHLORIDE/SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE, AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.